Heat Transfer Coefficient Converter

Convert W/(m²·K), BTU/(h·ft²·°F), kcal/(h·m²·°C) and related U-value units.

Result

0.17611 BTU/(h·ft²·°F)

1 W/(m²·K) = 0.17611 BTU/(h·ft²·°F)

All units for this value
UnitSymbolValue
Watt per m² per kelvinW/(m²·K)1
Watt per m² per °CW/(m²·°C)1
Kilowatt per m² per kelvinkW/(m²·K)0.001
Watt per cm² per °CW/(cm²·°C)0.0001
Kilocalorie (IT) per hour per m² per °Ckcal/(h·m²·°C)0.859845
Calorie (IT) per second per cm² per °Ccal/(s·cm²·°C)0.0000238846
BTU (IT) per hour per ft² per °FBTU/(h·ft²·°F)0.17611
BTU (IT) per second per ft² per °FBTU/(s·ft²·°F)0.0000489195

About this calculator

The heat transfer coefficient, often called a U-value, describes how much heat passes through a surface per unit area for each degree of temperature difference across it, a key figure in building insulation and equipment design. This converter switches between the SI unit W/(m²·K) and the BTU/(h·ft²·°F) unit widely used in US building codes.

How it works in plain English

A heat transfer coefficient combines a power unit, an area unit, and a temperature-interval unit into one compound measurement, so the converter anchors every value to watts per square meter per kelvin. Because a kelvin and a Celsius degree represent the same size step, W/(m²·K) and W/(m²·°C) are identical numbers, letting the converter treat them as the same unit.

The BTU-based unit divides the International Table BTU (1055.05585262 joules) by an hour (3600 seconds), a square foot (0.09290304 m²), and a Fahrenheit degree (five-ninths of a kelvin), combining to a factor of about 5.678263 W/(m²·K) per BTU/(h·ft²·°F). This is why US-published window and wall U-values, which are often small numbers like 0.3, correspond to noticeably different-looking metric U-values.

Enter a value with your chosen from and to units, and the result updates immediately, backed by a full table of the same coefficient expressed in every supported unit. A precision control sets how many decimal places display, and a swap button reverses the two selected units in one click.

The formula

  • value_in_target = value_in_source × (source factor to W/(m²·K)) ÷ (target factor to W/(m²·K))
  • 1 BTU(IT)/(h·ft²·°F) = 1055.05585262 ÷ 3600 ÷ 0.09290304 ÷ (5/9) = 5.678263 W/(m²·K)
  • 1 kcal(IT)/(h·m²·°C) = 4186.8 ÷ 3600 = 1.163 W/(m²·K)
  • 1 W/(m²·°C) = 1 W/(m²·K)

Worked example

Suppose a US window specification lists a U-value of 0.30 BTU/(h·ft²·°F), typical of a good double-glazed unit, and an architect wants that expressed in the metric W/(m²·K) form used on a European energy-efficiency label. Multiplying by the conversion factor: 0.30 × 5.678263 = 1.7035 W/(m²·K).

Entering 0.30 into the BTU/(h·ft²·°F) field with W/(m²·K) selected as the target returns about 1.7035 W/(m²·K) immediately. As a sanity check, that result falls within the roughly 1.4-2.8 W/(m²·K) range typically quoted for double-glazed windows, so it lines up with what's expected for that type of glazing rather than looking like an outlier. The full unit table also shows this same U-value equals roughly 1.4645 kcal/(h·m²·°C), confirming the window performs similarly whichever labeling standard is used to describe it.

Heat transfer coefficient (U-value) reference values

QuantityValue in W/(m²·K)
1 BTU(IT)/(h·ft²·°F)5.678263
1 kcal(IT)/(h·m²·°C)1.163
Single-pane window (typical)≈5.7-6.0
Double-glazed window (typical)≈1.4-2.8
Well-insulated wall (typical)≈0.2-0.4

Standard unit definitions and typical building component ranges

Frequently asked questions

What does a lower U-value mean for a building material?

A lower U-value means less heat passes through the material for a given temperature difference, so the material insulates better. This is the opposite of R-value, where a higher number means better insulation; U-value and R-value are reciprocals of each other once matching units are used.

Why is 1 BTU/(h·ft²·°F) worth about 5.68 W/(m²·K)?

That factor is the product of four separate conversions applied together: the BTU-to-joule factor, the hour-to-second factor, the square-foot-to-square-meter factor, and the Fahrenheit-degree-to-kelvin factor. Multiplying the BTU and dividing by the other three gives the combined figure of approximately 5.678263 used throughout this converter.

Are W/(m²·K) and W/(m²·°C) really the same unit?

Yes. A one-kelvin temperature difference and a one-degree-Celsius temperature difference are exactly the same size, differing only in where their zero points sit. Since a heat transfer coefficient depends on the size of the temperature difference rather than an absolute temperature, both notations give identical numeric results.

How does a U-value relate to thermal resistance or R-value?

A U-value is the mathematical reciprocal of the total thermal resistance across a surface, once consistent units are used, so a material with double the R-value has half the U-value. This converter focuses on U-value units directly; a separate thermal resistance converter handles R-value-style units.

Can I compare a US window rating directly against a European one?

Yes, once both are converted into the same unit. Enter the US BTU/(h·ft²·°F) figure, select W/(m²·K) as the target, and compare the result against the European label's stated value. Because both describe the same physical property, a correct conversion makes the two ratings directly comparable.